Mechanical model validation with geometry-linked UFF data
One UFF handoff
Geometry, waveforms and FRFs
XYZ coordinates, tri-axial velocity waveforms and FRFs remain associated with each measurement record.
A direct path from test to FE correlation
1. Define
Set the geometry, test points, response directions and excitation reference.
2. Measure
Capture dense non-contact velocity data and combine it with force, acceleration, displacement or strain references.
3. Correlate
Review modes, frequency and damping estimates, FRF overlays, MAC, COMAC and other correlation indicators.
4. Update
Focus the model on the joints, boundaries, material properties and local stiffness that drive the mismatch.
Keep response location and direction intact
Link point and response
Geometry and response records arrive together, so channels do not need to be reconstructed against coordinates.
Preserve direction
XYZ output identifies the response direction at each test degree of freedom.
Start analysis sooner
Import the test model and move into visualisation, parameter estimation and correlation.
See the regions that drive the mismatch
Complex structures
Cover panels, assemblies, frames and larger structures with the spatial detail needed to interpret the measured response.
Small components
Measure local mode shapes where conventional sensor placement is intrusive, impractical or too sparse.
Measure small features without a dense sensor array
Use Laser RADAR for coverage and retain the complete test model
UFF export
Transport test geometry and structural-dynamics data into the modal and correlation environment your team uses.
Geometry-aware review
Open a test model with points, directions, waveforms and FRFs linked before animation or correlation begins.
Your analysis workflow
Keep your existing analysis package, naming conventions and validation criteria.
Resources for the next model-validation decision
Full-field modal-analysis workflow guide
Follow the end-to-end workflow from excitation and FRF acquisition through curve fitting, MAC review and UFF export.
Impact-test application note
See an impact-hammer test on a concrete slab using 65 simultaneous response measurements and geometry context.
PCB vibration application note
Explore high-density response measurement on populated electronics where local component behaviour drives qualification risk.
Products and application context
Q2 Laser RADAR
For complex parts, dense dynamic coverage and integrated 3D geometry in one measurement workflow.
Q1 Laser RADAR
For large or difficult-to-access structures that need stand-off geometry capture and vibration insight.
Acoustics, noise and vibration applications
Browse vibration, modal-testing and NVH applications by engineering question, structure and measurement constraint.
Practical answers before you plan the test
L’export peut conserver géométrie, coordonnées et résultats vibratoires Q-Series pour des outils compatibles, y compris réponse et FRF lorsque l’essai fournit la référence d’entrée requise. Confirmez le jeu UFF, les unités, la convention de coordonnées et les besoins de l’outil récepteur pour la version et le flux.
Une FRF relie la réponse structurelle mesurée à une entrée mesurée selon la fréquence. Dans un essai modal au marteau ou pot vibrant, elle aide à identifier les résonances, estimer les paramètres modaux et comparer l’essai au modèle éléments finis. Un spectre de sortie seul n’est pas automatiquement une FRF.
Oui, si la force du marteau est acquise comme référence d’entrée alignée temporellement et si le Laser RADAR enregistre la réponse sur la géométrie choisie. Déclenchement, temps, directions, bande, fenêtrage et qualité de force doivent être maîtrisés avant calcul ou export des FRF.
Alignez système de coordonnées, points, directions de réponse, unités, conditions aux limites et d’exploitation, plage de fréquence et grandeur comparée. Une correspondance claire rend interprétables les écarts de fréquence propre, amortissement, forme modale et FRF au lieu d’artefacts de montage.
Oui. Les ingénieurs peuvent examiner FRF ou paramètres modaux mesurés, les comparer aux prédictions et guider les mises à jour avec les écarts. Le logiciel ne valide ni ne met à jour automatiquement le modèle ; choix des paramètres, critères et interprétation restent dans l’analyse.
Non. UFF est un format d’échange qui accélère le transfert de géométrie et données compatibles. Identification modale, corrélation, mise à jour, revue des incertitudes et rapport exigent toujours un logiciel adapté, une méthode définie et un jugement d’ingénierie qualifié.